A soft wash mix is a dilution problem. You have a strong product, you want a weaker mix, and you need to know how much of each goes in the tank. The arithmetic is simple, but it is easy to get wrong on a tailgate with a half-empty jug, and getting it wrong in either direction costs you. Too weak and the job does not clean. Too strong and you risk the plants, the surface and yourself. This calculator does the math and shows its work. It does not tell you what strength to use. That comes from the people who make the chemical and the surface.
How the calculator works
There are two ways crews apply a soft wash mix, and the calculator does both.
- One tank, sprayed as mixed. You mix the strength you want to spray in one tank. The calculator tells you how much sodium hypochlorite and how much water make that, in gallons and fluid ounces.
- Through a downstream injector. The injector pulls the tank mix into a stream of plain water near the nozzle. If it draws 1 part of mix for every 10 parts of water, the mix is cut to one eleventh before it reaches the wall. So the tank has to be eleven times stronger than what you want at the surface. The calculator works out that tank strength and how to mix it. If your product is not strong enough to get there, it says so and tells you the most you can reach.
- Surfactant. If you add a surfactant, enter the fluid ounces per finished gallon from its label. It takes up room in the tank, so the water is cut by the same amount.
The formula
This is the standard dilution equation, strong volume times strong strength equals weak volume times weak strength (C1 x V1 = C2 x V2):
- Product (gallons) =
batch x strength in the tank / strength of the product - Surfactant (gallons) =
batch x fluid ounces per gallon / 128 - Water (gallons) =
batch - product - surfactant - Injector: strength in the tank =
strength at the surface x (water parts + 1) - Injector: most you can reach at the surface =
strength of the product / (water parts + 1)
There are 128 fluid ounces in a US gallon.
Worked example
One tank. You pour in 12.5% sodium hypochlorite and want 3% on the surface. You are making a 5 gallon batch.
- Product: 5 x 3 / 12.5 = 1.2 gallons (153.6 fluid ounces).
- Water: 5 - 1.2 = 3.8 gallons (486.4 fluid ounces).
- That is 3.17 parts water for each part of product. Check: 1.2 gallons at 12.5% is the same amount of chlorine as 5 gallons at 3%, because 1.2 x 12.5 = 15 and 5 x 3 = 15.
With a surfactant. Add 2 fluid ounces per gallon and the 5 gallon batch holds 10 fluid ounces of it (0.078 gallons). The water drops to 3.72 gallons. The product stays at 1.2 gallons.
Through an injector that draws 5 parts water to 1 part mix. You want 2% on the surface from a 12.5% product, in a 5 gallon chemical tank.
- The injector cuts the mix to one sixth (1 part in 5 + 1), so the tank has to be 2% x 6 = 12%.
- Product: 5 x 12 / 12.5 = 4.8 gallons. Water: 0.2 gallons (25.6 fluid ounces).
- The most this product could ever give at the surface through that injector is 12.5% / 6 = 2.08%. You are close to the limit.
A target the product can't reach. You want 1.5% from the same product through a 10 to 1 injector. The tank would need 1.5% x 11 = 16.5%, which is stronger than the 12.5% you started with. The most you can reach is 12.5% / 11 = 1.13%. The calculator stops and says so. The fix is a stronger product, a lower injector ratio or a lower target.
What the mix costs. Say your product costs $5 a gallon (use your own price). The 1.2 gallons in the first example is $6.00 for the 5 gallon batch, or $1.20 for each finished gallon. That is the number to carry into the chemical line of your pressure washing price. Chemicals are only a small part of a soft wash price. Time, travel and your minimum charge matter much more.
Safety
Soft washing uses a corrosive oxidizer around people, plants, pets and drains. Treat the mixing as the most dangerous part of the job.
- Read the safety data sheet (SDS) for every product. Section 8 lists the protective equipment the maker calls for, section 7 covers handling and storage, and section 10 lists what the product must not be mixed with. Keep the sheets in the truck.
- Wear the protection the SDS calls for. For concentrated sodium hypochlorite that normally means eye protection that seals against splashes, chemical-resistant gloves and clothing that covers your skin. Concentrated sodium hypochlorite can seriously damage an eye, so keep goggles on whenever the jug is open.
- Never mix sodium hypochlorite with acids or ammonia. The CDC says solutions of it can give off dangerous amounts of chlorine or chloramine when mixed with acids or ammonia, and household bleach can give off chlorine gas when mixed with other cleaners. That includes rust removers, toilet bowl and acid-based cleaners, and anything with ammonia in it. Rinse your mixing containers and keep the jugs apart.
- Mix where there is moving air, and keep the lid on. Do not mix in a closed van or garage.
- Order of adding. A common rule for strong chemicals is to put water in the tank first and add the product to it, which limits splashing. Check your SDS.
- Storage. The CDC advises keeping hypochlorite solutions in tightly closed bottles, away from acids and sunlight, and no warmer than about 68 degrees F (20 degrees C). Sodium hypochlorite weakens with age, heat and light, so the strength on an old or hot-stored jug is not the strength in it.
- Plants and pets. Wet down plants, grass and shrubs near the work before, during and after, as many operators do. Tell the customer to keep people and pets away until everything is rinsed and dry.
- Runoff. Keep wash water out of storm drains. Rules on what you may let run off, and what you must catch, differ by city and state, and some places treat the water as a discharge. Call your local stormwater office before you guess.
- The label is the law. Many sodium hypochlorite products are EPA-registered pesticides, and federal law makes it unlawful to use a registered pesticide in a way its label doesn't allow (FIFRA, 7 U.S.C. 136j(a)(2)(G)). Check the label for the surfaces and strengths it allows, and ask your state pesticide agency whether cleaning roofs or siding for pay needs an applicator license.
- First aid. Know where the eyewash is before you open the jug. In an emergency, call poison control at 1-800-222-1222 (in the US) or 911.
What the calculator does not know
- Percent on the label is by weight, and the math is by volume. Dilution by volume is how the trade does it and it is close enough for a spray mix. Strong sodium hypochlorite is denser than water, so the real strength at the surface can differ from the calculator by a few percent. If you need an exact number, measure the finished mix.
- Strength drifts. Aged product is weaker than its label. A mix made from a hot jug in July will not match the same recipe made from fresh product.
- Your tank marks. The math is only as good as your measuring. Check your tank by pouring in a known number of gallons of water and marking the level.
- Injector ratio on paper vs in the field. Injectors draw differently with different hose lengths, tip sizes and pump pressures. Time the draw on your own rig.
Common mistakes
- Guessing from the old jug. If you do not know the strength, you do not know the mix. Read the label every time you open a new jug.
- Forgetting the injector dilution. Mixing the tank at the strength you want on the wall, then running it through an injector, gives you a fraction of that.
- Mixing for the ratio, not the strength. "50/50" means something very different with a 6% and a 12.5% product.
- Skipping the rinse. Mixed product left in a hose or pump eats seals and fittings, and the next crew member pays for it.
- Telling the customer a number as if it were a promise. You can explain the method to a customer, but a particular strength is a working setting for your surface, not a guarantee.
FAQ
What is a soft wash?
A soft wash cleans with a chemical mix at low pressure instead of high pressure alone. It is used on roofs, siding and other surfaces that high pressure can damage. The mix does the cleaning, which is why the strength matters so much.
How much 12.5% sodium hypochlorite do I need for a 5 gallon batch at 3%?
1.2 gallons of product and 3.8 gallons of water. That is the arithmetic. Whether 3% is right for your surface is a question for your chemical maker and the surface maker.
Why does the calculator say my injector can't reach my target?
An injector dilutes the mix, so the strongest you can spray is the strength of your product divided by the water parts plus one. A 12.5% product through a 10 to 1 injector can never go above 1.13% at the surface. Pick a stronger product, a lower injector ratio or a lower target.
Does the strength change as the product ages?
Yes. Sodium hypochlorite loses strength with age, heat and sunlight. Buy what you will use, keep it cool and out of the sun, and treat the label as the strength it started at.
Is the percent by volume or by weight?
The label strength is a percent of available chlorine by weight. The calculator treats it as a straight dilution by volume, the way the trade mixes. The difference is small for a spray mix, but if you need to be exact, measure the finished mix.
Can I use this for roofs?
The calculator will do the arithmetic for any strength. The right strength for a roof depends on the roofing. The Asphalt Roofing Manufacturers Association publishes cleaning guidance for asphalt shingles, and each shingle maker's warranty has its own rules. Follow those, not a forum thread.
How do I price the job once I have the mix?
Start from your time, not the chemical. The pressure washing price calculator takes a chemical cost per 100 square feet, adds your labor, setup and a minimum charge, and prices it at your margin. Use the cost per finished gallon from this page to work out the chemical cost.
Sources
- Centers for Disease Control and Prevention, Calcium hypochlorite / sodium hypochlorite medical management guideline: household and commercial strengths, the warning about mixing with acids or ammonia, and storage.
- Centers for Disease Control and Prevention, Chlorine chemical fact sheet: household bleach can release chlorine gas when mixed with some other cleaners.
- U.S. EPA, NPDES stormwater program: why wash water and chemicals should not reach storm drains. Local rules vary.
- Your product's own safety data sheet and label, and the siding or shingle maker's cleaning instructions. They override anything on this page.
- Dilution is the standard C1 x V1 = C2 x V2 relation. The default numbers (12.5%, 3%, 5 gallons) are examples chosen to show the math.